| RAID |
|
Multiple arrays with Dedicated, Global, or
Enclosure-specific hot spares
RAID levels supported: RAID 0, 1 (0+1), 3, 5, 6,
10, 30, 50, 60, and NRAID
ASIC400 backbone
Configurable stripe size and write policy per
array
Automatic background rebuild
Online expansion by:
-- Adding new drives -- Copying and
replacing drives with drives of larger capacity
Independent array stripe size and write
policy
Intelligent drive handling:
-- In degraded mode: skips irreparable blocks to continue
rebuild -- In normal operation:
data-block verification and repair
Intelligent reactive and preventive mechanisms:
-- Automated cache flush --
Automated Media Scan -- Automated
caching mode
|
| Subsystem
Components |
|
Single or Redundant controller configuration
Compact steel and aluminum alloy enclosure
Two (2) or one (1) RAID controller modu
Three (3) hot-swappable, redundant, 405W power
supply units
Two (2) hot-swappable, redundant, thermal fan
cooling modules
Twenty-four (24) hot-swappable drive trays
Two (2) forearm handles
Two (2) hot-swappable battery backup units (BBUs) |
| Host
Interface |
|
Four (4) 4G-FC host channels with embedded bypass to eight
(8) Fibre ports
Tagged command queuing up to 256
Variable stripe size per logical drive
Optimization setting for random or sequential
I/Os |
| Drive
Interface |
|
Twenty-four (24) hot-swappable 3Gbps SATA-II (3Gbps) drive
trays
Automatic bad sector reassignment
Dedicated bandwidth to each connected drive |
| Management |
|
Firmware-embedded utility via LCD keypad or RS-232C port
VT-100 terminal emulation via RS-232C
Telnet access via the onboard Ethernet port
10/100 BaseT Ethernet for out-of-band management
Two (2) COM ports for local access to
firmware-embedded utility and UPS connectivity
Java-based SANWatch software with Snapshot
protection:
-- Graphical user interface --
Local/remote management; in-band or out-of-band via TCP/IP --
Centralized management to monitor and administer multiple
RAID units on
one screen -- Secure link over SSL
Configuration Client for easy access to the
configuration utility screen
SNMP 2.0 MIBs with get and set commands |
| SAN
Management |
|
Up to 1024 LUNs (if sufficiently large memory is used with
the proper settings) |
|
Infortrend Smart
Technologies
|
|
Derived from a decade of experience in RAID storage
design, Infortrend's innovative firmware delivers Smart
technologies that provide enhanced storage solutions for
every customer environment, from small organizations to
large enterprises. These technologies enhance I/O
processing, drive handling, and system management |
| Indicators |
|
Onboard alarm
Module status LED indicators:
-- Two (2) per drive tray -- Three
(3) per LCD panel
-- Seven (7) per RAID controller module --
Two (2) per Ethernet port
-- Two (2) per cooling module -- One
(1) per power supply unit
-- One (1) per BBU module -- Two (2)
per FC port Module failure alert
through I2C bus
Event notifications sent over email, fax, LAN
broadcast, SNMP traps, MSN
messenger, SMS short messages
System alerts through Java-based RAIDWatch
manager |
| IOSmart |
|
IOSmart allows for the flexible configuration of logical
drives, logical volumes and logical partitions and ensures
instant RAID availability via background logical drive
initialization. Fibre loops' load balancing is provided
within the subsystem. The firmware' s Adaptive Write
Policy and Guaranteed Latency I/O algorithms improve write
performance and ensure fast and continuous data flow. |
| DrvSmart |
|
The
DrvSmart utilities manage disk drive defects and help
ensure data integrity. One of the main DrvSmart functions,
Media Scan, retrieves data from degraded or damaged hard
drives and handles low quality drives in both the degraded
mode and during the rebuild process. Other DrvSmart
features include disk cloning, drive roaming, SMART,
transparent resetting of non-responsive hard drives, RAID
parity update tracking and recovery. |
| SysSmart |
|
SysSmart combines enclosure monitoring and firmware
management capabilities in order to minimize the chance of
down time caused by hardware failures. The SysSmart
functions include the event-triggered cache flush and the
various monitoring approaches combined with the powerful
RAIDWatch manager. Component status, voltage and
temperature readings, and system events are instantly
revealed through the manager's graphical interface. |
| Interfaces |
|
Eight (8) or four (4) FC ports that receive SFP fiber
optic transceivers
Two (2) COM ports on each controller module for
RS-232C serial port (
38400, n, 8, 1) and UPS support
One (1) 10/100BaseT Ethernet port on each
controller module |
| Power
Supply Module |
|
Three (3) redundant, hot-swappable power supplies with PFC
Input: 100V at 16A, 240V at 8A with PFC
(auto-switching) 50 to 60 Hz
output: (Maximum output: 405 Watts) +12v 24a max;
+5v 36a max |
| Cooling
Module |
|
Two (2) redundant, dual-fan cooling modules
Maximum Air Flow: High speed: 48.12 CFM |
| Dimensions: |
|
Chassis without handles: 445(W) x 174.4(H) x 498(D) mm
(17.5 x 6.86 x 19.6 inches)
Chassis with handles: 482(W) x 174.4 (H) x
514(D) mm (19 x 6.86 x 20.2
inches)
Package: 520(H) x 580(W) x 780(D) mm (20.5 x
22.8 x 30.7 inches) |
| System
Weight |
|
Net weight: 38kg (w/o drives)