Servon KSC- A16F-R2431 Storage |
|
|
|
KingStar
Server Systems
As one of the world's best-selling server lines,
KingStar servers provide customers with long-term
dependability. Designed and built with quality, KingStar
solutions are able to handle any business-critical
applications. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
FC-4G to SATA-II
(3Gbps) RAID subsystem |
| |
Eight (8)
FC-4G host ports w/ onboard bypass |
| |
Redundant,
active-active RAID controllers |
| |
Hardware RAID6
XOR , ASIC400 chipset |
|
Intelligent
load-balancing; internally & between host
links by the EonPath multi-path software |
| |
High-availability,
modular enclosure design |
| |
Up to 2GB
cache per controller |
|
|
|
|
|
|
| Order Now Contact Us |
| For system changes and upgrades. Please Call 408-736-8590
for Sales Assistant |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| RAID
Controller |
|
Hardware RAID parity computing
Supports RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50,
60, and NRAID
RAID Migration
Configurable stripe size and write policy per
array
Multiple Global, Dedicated, &
Enclosure-specific hot-spares
Intelligent Drive Handling:
-- In degraded mode: skips irreparable blocks to continue
rebuild -- In normal operation:
data-block verification and repair
|
| Host
Interface |
|
Eight (8) FC-4G host port w/HUB functions
Concurrent I/O commands
Tagged command queuing up to 256
Adaptive cache write policies |
| Drive
Interface |
|
Sixteen (16) 3.0Gbps SATA-II (3Gbps) , hot-swappable drive
trays
Accommodates 1-inch pitch, 3.5-inch SATA-II
(3Gbps) disk drives
S.M.A.R.T. and NCQ support· Automatic
bad-sector reassignment
Dedicated bandwidth to each connected drive |
| System
Components |
|
Heavy duty 3U enclosure
Dual-redundant RAID controller modules
One (1) 512MB DDR RAM DIMM module (default,
supports up to 2GB in size) on each controller
Two (2), hot-swappable, redundant, 530W power
supply units
Two (2), redundant, dual-speed cooling modules
Sixteen (16), hot-swappable drive trays
Two (2) forearm handles
LCD keypad panel
Li-Ion, life expectancy & charge level aware
battery backup unit (BBU) |
| Management |
|
COM1 serial port for local access to firmware-embedded
utility
COM2 for UPS connection
GUI, Telnet, and SSH system monitoring via
Ethernet
Browser-based or Java-based RAIDWatch manager
software
Firmware-embedded manager via RS-232C (audio
jack) that is platform independent
Widest range of event notification methods
including email, LAN broadcast, fax, SNMP traps, SMS,
and MSN
LCD keypad panel to all configuration options
Variable logical drive options per DIMM size
Module status LED indicators
Two (2) per drive tray
Seven (7) per controller module
One (1) per power supply unit
One (1) per BBU module
Two (2) per cooling module
Module failure alert through I 2 C
bus |
| Interfaces |
|
One
(1) Fast Ethernet management port
Two (2) serial COM port (38400, n, 8, 1)
Power Supply Module Two (2) redundant hot-swappable power
supplies with PFC
-- Input: 100~240VAC with 530W PFC (auto-switching) 47 to
63Hz. -- utput: (Maximum output: 530
Watts) +12V 30A max; +5V 32A max;
+3.3V 32A max. |
| Cooling
Module |
|
Two (2) redundant dual-fan cooling modules
Maximum air flow: -- High
speed: 90 CFM -- Low speed: 70 CFM |
| Environmental
Specifications |
|
Operating temperature: 0Ί to 40ΊC (35ΊC w/ battery)
Non-operating temperature: - 40Ί to 60ΊC
Relative humidity: 5 to 95%, non-condensing
Altitude: Operating: sea level to 12,000 ft
Non-operating: sea level to 40,000 ft |
| Dimensions |
|
Chassis
without handles: 445(W) x 130(H) x 488.2(D) mm (17.5' x
5.1' x 19.2)
Chassis with handles: 482.6(W) x 131(H) x
504.3(D) mm (19' x 5.2' x 19.9') Package:
423(H) x 567(W) x 772(D) mm (16.7 x 22.3 x 30.4 inches |
|
System weight |
|
2x190mm blower fans
Gross weight: 31kg (without drives) |
| |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|